EMX3 Specifications
<>>
| General |
|
| Current Range |
23 A ~ 1600 A (nominal) |
| Motor connection |
In-line or inside delta |
| Bypass |
Integrated internal or external |
| Supply |
|
| Mains Voltage (L1, L2, L3) |
|
| EMX3-xxxx-V4 |
200 VAC ~ 440 VAC (± 10%) |
| EMX3-xxxx-V7 |
380 VAC ~ 690 VAC (± 10%) (in-line connection) |
| EMX3-xxxx-V7 |
380 VAC ~ 600 VAC (± 10%) (inside delta connection) |
| Control Voltage |
(A1, A2, A3) 110 ~ 220 VAC (+ 10% / -15%) |
|
or 230 ~ 440 VAC (+ 10% / -15%) |
| Mains Frequency |
45 Hz to 66 Hz |
| Inputs |
|
| Inputs |
Active 24 VDC, 8 mA approx. |
| Start (C23, C24) |
Normally open |
| Stop (C31, C32) |
Normally closed |
| Reset (C41, C42) |
Normally open or closed |
| Programmable Inputs |
|
| Input A (C53, C54) |
Normally open or closed |
| Input B (C63, C64) |
Normally open or closed |
| Motor Thermistor (B4, B5) |
|
| PT100 RTD (B6, B7, B8) |
|
|
|
| Outputs |
|
| Relay outputs |
10 A at 250 VAC resistive |
|
5 A at 250 VAC, AC15 pf 0.3 |
| Run Relay (23, 24) |
Normally Open |
| Programmable Outputs |
|
| Relay A (13, 14) |
Normally Open |
| Relay B (31, 32, 34) |
Changeover |
| Relay C (41, 42, 44) |
Changeover |
| Analog Output (B10, B11) |
0-20 mA or 4-20 mA |
| 24 VDC Output (P24, COM) |
200 mA |
| Environmental |
|
| Protection |
|
| EMX3-0023B ~ EMX3-0105B |
IP20 & NEMA1 |
| EMX3-0145B ~ EMX3-1600C |
IP00 |
| Operating temperature |
-10 °C ~ 60 °C |
| Storage temperature |
- 10 °C ~ 60 °C |
| Humidity |
5% to 95% Relative Humidity |
|