MVX: Specifications
| Mains Voltage |
|
|
MVXxxxx-V12
|
12 kV Phase-phase |
| Rated Frequency |
50 Hz or 60 Hz |
| Rated Power Frequency Withstand Voltage (Ud) |
|
MVXxxxx-V12
|
42 kV |
| Rated Lightning Impulse Withstand Voltage (Up) |
|
MVXxxxx-V12
|
75 kV |
| Rated short-time withstand current (asymmetrical RMS peak) (Ik) |
|
MVXxxxx-V12
|
31.5 kA for 4 seconds |
| Form Designation |
Bypassed semiconductor motor starter form 1 |
| Start (Terminals C23, C24) |
24 VDC, 8 mA approx |
| Stop (Terminals C31, C32) |
24 VDC, 8 mA approx |
| Reset (Terminals C41, C42) |
24 VDC, 8 mA approx |
| Input A (Terminals C53, C54) |
24 VDC, 8 mA approx |
| Input B (Terminals C63, C64) |
24 VDC, 8 mA approx |
| Motor Thermistor (Terminals B4, B5) |
Trip point > 2.8 kOhm |
| Relay Outputs |
10 A @ 250 VAC resistive |
|
6 A @ 250 VAC AC15 p.f. 0.3 |
| |
10 A @ 30 VDC resistive |
| Main Contactor (Terminals 13, 14) |
Normally Open |
| Bypass Contactor (Terminals 23, 24) |
Normally Open |
| Run Output/ PFC (Terminals 33, 34) |
Normally Open |
| Output Relay A (Terminals 43, 44) |
Normally Open |
| Output Relay B (Terminals 51, 52, 54) |
Changeover |
| Output Relay C (Terminals 61, 62, 64) |
Changeover |
| Analog Output (Terminals B10, B11) |
0-20 mA or 4-20 mA |
| Equipment Class (EMC) |
Class A |
| Internal Arc Classification (IAC) |
AFLR to maximum of 31.5 kA for 1 second |
| Degree of Protection |
|
| Phase Cassette |
IP00 |
| Controller |
IP54/ NEMA 12 |
| Operating Environment |
|
| IEC60721-3-3: IE34: Climatic 3K4 |
-5° C to 40° C, with derating to 55° C |
| Relative Humidity |
5% to 95% |
| Storage Environment |
|
| IEC60721-3-1: IE12 |
- 5° C to + 45° C |
| Relative Humidity |
5% to 95% |
| Pollution Degree |
Pollution Degree 2 |
| Vibration |
IEC 60068-2-6 Fc |
|
| C√ |
EMC requirements |
| CE |
EMC EU Directive |
MVX Protection Codes
| 48 |
Maximum start time |
Excess start time |
| 66 |
Too many starts |
Restart delay and dynamic thermal model |
| 37 |
Undercurrent |
|
| 51L |
Load Increase (alarm) |
High current frequency output |
| 51R |
Overcurrent - jam |
Excess start time, electronic shearpin |
| 50 |
Overcurrent - short |
Shorted SCR, electronic shearpin |
| 49/51 |
Thermal overload |
Thermal overload - dynamic model |
| 46 |
Current imbalance |
Current imbalance |
| |
Positive/negative phase sequence |
Phase sequence |
| 27 |
Undervoltage |
Undervoltage |
| 59 |
Overvoltage |
Overvoltage |
| 47 |
Phase loss |
Phase loss |
| 47 |
Phase sequence |
Phase sequence |
| 50G |
Ground fault |
Ground fault |
| 3 |
Communications failure |
Communications failure |
| 3 |
Internal failure |
Internal failure |
| 86/97 |
Ext. fault 1/code - 1 |
Auxiliary trip A |
| |
Ext. fault 1/code - 2 |
Auxiliary trip B |
| 38 |
Motor overtemperature |
Thermistor protection* |
| 49 |
Stator winding overtemperature |
Thermistor protection* |
| 32 |
Under power |
Power Loss |
* RTD Relay is an optional extra.
|